= System Properties= | = System Properties= | ||
Line 12: | Line 10: | ||
mxe.mbocount=1 | mxe.mbocount=1 | ||
mxe.logging.CorrelationEnabled=1 | mxe.logging.CorrelationEnabled=1 | ||
Caso esteja atrás de um load balancer | |||
mxe.system.usingLoadBalancer=1 | |||
= Java Virtual Machine = | |||
* [[IBM Maximo: Java Virtual Machine Properties for IBM WebSphere]] | |||
= Logging = | = Logging = | ||
Line 32: | Line 38: | ||
! Schedule !! History Records !! Description | ! Schedule !! History Records !! Description | ||
|- | |- | ||
| less than 1d || | | less than 1d || 100 || - | ||
|- | |- | ||
| 1d | | 1d to 1 week || 100 || history of the last 100 days (3 months) | ||
|- | |- | ||
| 1w || 10 || history of the last 10 weeks (3 months) | | 1w or greater || 10 || history of the last 10 weeks (3 months) | ||
|} | |} | ||
== Disable unused Crontask == | == Disable unused Crontask == | ||
Line 53: | Line 58: | ||
== Disable Comm Log Entry == | == Disable Comm Log Entry == | ||
In Communication Templates, there is a checkbox called '''Comm Log Entry''' which when checked records an entry in the COMMLOG table. | In Communication Templates, there is a checkbox called '''Comm Log Entry''' which when checked records an entry in the COMMLOG table. | ||
Disabling reduce database transaction and reduce size of table COMMLOG. Exists another checkbox '''Tracked Failed Messages?''', that record fails. | |||
= Ver também = | = Ver também = |
Latest revision as of 22:14, 23 June 2022
System Properties
Para detalhes veja artigo IBM Maximo: System Properties
mxe.crontask.donotrun and mxe.crontask.dorun mxe.db.logSQLTimeLimit=1000 mxe.db.closelongrunconn=true mxe.db.longruntimelimit=60 mxe.db.detectlongrunconninterval=30 mxe.mbocount=1 mxe.logging.CorrelationEnabled=1
Caso esteja atrás de um load balancer
mxe.system.usingLoadBalancer=1
Java Virtual Machine
Logging
- Maximo DB Connection watchdog logger (log4j.logger.maximo.dbconnection)=INFO
- Define to INFO. Generate this message on logs. BMXAA7084I - The DbConnectionWatchDog class has been trying to close the database connection for:
Crontask & Escalation
Reduce CronTask History
Crontask/Escalation can store the task execution times. This feature is enable when mark ‘Keep history’ checkbox in crontask. This information is recorded in CRONTASKHISTORY table
I use the following table to define history records and reduce the size of CRONTASKHISTORY table:
Schedule | History Records | Description |
---|---|---|
less than 1d | 100 | - |
1d to 1 week | 100 | history of the last 100 days (3 months) |
1w or greater | 10 | history of the last 10 weeks (3 months) |
Disable unused Crontask
Important: Check if you not use these crontasks before disable it
- InstDepreciationCronTask – Asset depreciation calculator, if not used.
- KPICronTask
- Old Infolink Crontask - check for error BMXAA1477E on logs
Communication Templates
Disable Comm Log Entry
In Communication Templates, there is a checkbox called Comm Log Entry which when checked records an entry in the COMMLOG table.
Disabling reduce database transaction and reduce size of table COMMLOG. Exists another checkbox Tracked Failed Messages?, that record fails.