IBM Maximo: Integrity Check Tool

From Wiki
Revision as of 18:47, 6 July 2023 by Ebasso (talk | contribs) (→‎Solutions)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

Maximo has an internal tool called Integrity Checker for data integrity and it is also a recommended tool to confirm whether some upgrade process for example was successful.

You can use it for non-upgrade purposes too, specially if you suspect your Maximo data could be corrupted, since the tool reports data integrity issues to be fixed.

Below i show some messages and how to solve

Solutions

BMXAA0443E -- Erro - BMXAA0443E -- Error - Sequence MAXVARSSEQ not setup correctly

Solution find the highest value for sequence and update sequence:

Drop Sequence LOGINTRACKINGUSEQ ;
Create Sequence LOGINTRACKINGUSEQ Start With 3756493 Increment By 1 Nocache Nocycle ;
Update maxsequence Set maxreserved=3756493 Where sequencename='LOGINTRACKINGUSEQ';

BMXAA6292E Records exist in the Wogen table which need be deleted.

Ver também