IBM Connections: Aplicando CRs e iFixes no IBM Docs
Procedimento
Atividades Pré Fix
1) Clique Websphere Console -> Applications -> Application Types -> WebSphere enterprise applications,
2) Selecione os aplicativos
- IBMConversion
- IBMConversionSanity
- ViewerApp
- ViewerSanity
3) E clique no botão Export.
4) Após a geração dos links faça o download dos EARs para backup
5) via terminal Linux, log no DMGR
mkdir -p /opt/IBM/Backups cp -R /opt/IBM/WebSphere/AppServer/profiles/Dmgr01/config/cells/connectionsCell/IBMDocs-config /opt/IBM/Backups/.
Aplicando os Docs_2.0_CR3_if6
1) Download do Docs20CR2iFix3
mkdir -p /opt/IBM/Binaries/Docs20CR3iFix6 cd /opt/IBM/Binaries/Docs20CR3iFix6 unzip IBMConnectionsDocs_CR3_iFix006.zip
2) Aplicando o Fix Docs_2.0_CR3_if6
cd /opt/IBM/Binarios/Docs20CR3iFix6 python applypatch.py -u wsadmin -p <COLOCAR_A_SENHA> -f /opt/IBM/WebSphere/AppServer/profiles/Dmgr01/bin/wsadmin.sh
Realizando um Full Syncronization
Procedimento:
1) Acessar o IBM System Console
2) Selecione os nós do Connections
3) Clique em Ressincronização Completa
4) Reinicie os servidores
Ver também
- IBM Connections: Preparando o Ambiente para o IBM Docs
- IBM Connections:Reorg Connections Databases
- IBM Connections:Limpeza de diretórios
- Mais Artigos sobre IBM Connections IBM Connections